In today’s industrial and commercial facilities, reliable power monitoring is essential for maintaining operational efficiency, reducing downtime, and optimizing energy usage. The PowerLogic PM5650 (METSEPM5650) is a powerful and versatile energy and power quality meter designed to provide detailed insights into electrical system performance.
One of the key features of the PM5650 is its ability to analyze harmonics up to the 63rd order, helping facility managers identify power quality issues that can affect equipment performance and lifespan. By detecting harmonic distortions early, businesses can take corrective action and improve overall system reliability.
The meter is equipped with dual Ethernet ports, enabling seamless communication and integration into existing monitoring networks. This connectivity allows users to access real-time data, perform remote monitoring, and simplify system management across multiple locations.
For advanced diagnostics, the PM5650 offers waveform capture capabilities, allowing users to record and analyze electrical events in detail. Combined with its 1.1 MB onboard memory, the device can store valuable historical data for troubleshooting and performance analysis.
The PM5650 also features 4 Digital Inputs (DI) and 2 Digital Outputs (DO), providing flexibility for system integration and automation applications. Additionally, users can configure up to 52 alarms to receive notifications about critical power events, helping prevent costly disruptions and equipment failures.
The PowerLogic PM5650 is versatile and optimized for specialized applications across demanding electrical environments:
Sub-Billing & Multi-Tariff Energy Management: Supports up to 8 distinct tariff schedules, allowing facility managers to accurately track, allocate, and sub-bill energy consumption across different cost periods or departments.
WAGES Monitoring: Equipped with 4 digital inputs configured for WAGES (Water, Air, Gas, Electricity, Steam) monitoring. This allows the meter to act as a central hub, aggregating utility data beyond just electrical consumption.
Power Quality Analysis & Troubleshooting: Ideal for diagnosing internal electrical disturbances. It captures up to the 63rd harmonic distortion and utilizes high-speed waveform capture to pinpoint voltage sags, swells, and transient anomalies.
Network Gateway Functionality: Serves as a reliable Serial-to-Ethernet gateway. It aggregates downstream Modbus RS-485 serial devices and pushes data seamlessly to upper-level IT/OT building networks.
Preventative & Cost-Saving Maintenance: Tracks real-time variations in load current (including direct neutral and calculated ground current monitoring) to prevent overheating, equipment failure, or unexpected downtime.
Revenue-Grade Accuracy: Compliant with the stringent IEC 62053-22 Class 0.2S standard for active energy. It guarantees precision measurement required for high-stakes cost allocation and billing.
High Sampling Rate: Captures data at 128 samples per cycle, ensuring that no transient fluctuation or brief power anomaly goes undetected.
Comprehensive Diagnostics: Simultaneously monitors Current, Voltage (Phase-to-Phase up to 690V, Phase-to-Neutral up to 400V), Frequency, Active/Reactive Power, and Power Factor.
63rd Harmonic Distortion Analysis: Monitors individual harmonics to protect sensitive electronics from excessive heat and distortion.
Waveform Capture & Event Logging: Features onboard sag and swell detection with waveform snapshots for visual root-cause diagnostics.
1.1 MB Internal Memory: Safely logs up to 14 customizable parameters with flexible logging intervals. It maintains timestamped event, alarm, and min/max diagnostic logs even during network disruptions.
Dual-Port Ethernet (Daisy Chain): Features two RJ45 Ethernet ports supporting high-speed 10/100 Mbit/s transfers. This allows meters to be daisy-chained together, drastically reducing network cabling costs.
Multi-Protocol Versatility: Fully speaks the languages of modern building management and automation systems: Modbus TCP/IP, Ethernet/IP, BACnet/IP, Modbus RTU/ASCII (2-wire RS-485), and DNP 3.0 over Ethernet.
Embedded Web Server: Includes an onboard web browser interface for real-time viewing, setup diagnostics, and automated email alarm notifications without needing external software.
I/O Capabilities: Armed with 4 Digital Inputs and 2 Digital Outputs (Relays) for control commands, alarm relays, or utility pulse counting.
Smart Alarm Matrix: Program up to 52 configurable alarms to instantly flag over-current, voltage imbalances, or threshold breaches.
Compact Industrial Build: Standard 96mm x 96mm flush-mount design with an IP54-rated front face for dust and water splash protection, keeping it safe in harsh electrical panel environments.
By choosing the PowerLogic PM5650 from AMPS Electric Trading, you receive authentic Schneider Electric hardware coupled with professional technical consultation. Whether you are upgrading an existing facility or building a new automation panel, the PM5650 delivers the intelligence needed to lower utility bills and secure absolute network reliability.
AMPS Electric Trading supplies genuine Schneider Electric PowerLogic meters and power monitoring solutions, providing reliable products, technical support, and competitive pricing for industrial and commercial projects across the region.
Schneider Electric is globally recognized for delivering innovative solutions in energy management and automation.
The company’s products are trusted by engineers, contractors, consultants, and facility managers worldwide because of their:
The MTN647895 reflects Schneider Electric’s dedication to quality, innovation, and performance.
📍 Contact AMPS Electric Trading:
📧 contact@ampsqr.com
📞 +974 3033 8370
🌐 www.ampsqr.com
